- 澤任訂制
- FST動物實驗器械
- 瑞士ideal-tek鑷子
- 瑞士Dumont鑷子
- Weller
- Techni-Tool
- 瑞士Rubis鑷子
- arosurgica
- Genesee Scientific
- Gilder Grids
-
Entegris
- WEICON
- ACCURIS
- AIMS
- RMC鉆石刀
- Sipel鑷子
- 德國WIHA
-
Si-Mat
- Jokari
- Circuitmedic
-
Glissando病理切片掃描儀
- KNIPEX(凱尼派克)
- Swann-morton
- Cellpoint Scientific
- Swanstrom
- All-spec
-
新華器械
- Excelta
- MENDA
- MEISEI
- Erem
- Regine
-
OPTRASCAN病理掃描儀
- Benchmark
-
IDEAL
- 大龍儀器
- 五洋醫(yī)療
- Hozan(寶山)
- 3M
- Stoelting
- Roboz
-
Diatome鉆石刀
- Fine Science Tools
- PLATO
- NanoSoft
-
Avantama
-
PSI打擊器及配件
- Aptum
- xuron
- SPI
- ASI Instruments
-
上海一恒
-
上海雷磁
- Quantifoil
- 上海方需
- 蘇州六六
-
Hamilton
- ISMART
-
顯微鏡
-
Bonllmann
- AVEN
- 塔望科技
-
瑞典Haglof激光測距儀
- STILLE
-
美國安維迪
- 德國貝朗蛇牌
- Medline
-
蛋白純化系統(tǒng)
-
OHAUS奧豪斯
- 康博特森
- Ossila
-
賽寧(蘇州)生物
- Bernstein
- 潔盟清洗機
-
Ted Pella
-
晶圓切割
-
Omniprobe FIB全鎢取樣針
-
新產(chǎn)品
-
矩陣
-
器械盒
-
切割套裝
-
手套
-
樣品盒
-
吸筆及吸盤
-
晶圓及晶圓盒
-
樹脂及耗材
-
金剛石懸浮液
-
實驗室樣品瓶及杯子
-
實驗室防護
-
石蠟
-
移液器及管
-
離心管及支架
-
計時器
-
玻片儲存盒
-
焊接棒
-
微型小鏟
-
夾持器及微針
-
耳標(biāo)及耗材
-
縫合夾及縫合針
-
放大鏡
-
止血鉗
-
氮化硅膜
-
耗材
-
導(dǎo)電膠及膠帶
-
骨剪及剪刀
-
膠帶及標(biāo)簽
-
顯微載玻片
-
碳粉及碳棒
-
切片機刀片
-
切片模具
-
電鏡載網(wǎng)
-
刀類
-
化學(xué)生物制樣
-
組織標(biāo)記染料
-
鉗子
-
樣品臺
-
拋光布
-
藍寶石基片
-
吸筆
-
打孔器
-
云母片
-
AFM用品
-
鉆石劃線筆
-
樣品臺盒
-
筆
-
儀器
-
晶圓鉗
-
晶圓切割
- DSI
- Keller
-
Smart Tweezers
- 瑞士PB
-
Microscopes Internat...
- Lattice Gear
-
凱氏定氮儀
- lindstrom
- 美國EMS
-
1-material
-
儀器
- realisticflies
- Boive
- Zivic
Potentiostats are control and measurement devices designed to output a controlled potential. Unlike other voltage sources, potentiostats contain feedback circuitry between the output and measured potential. This enables them to maintain a set potential through a circuit with varying resistance by increasing or decreasing the output, ensuring that the measured potential remains constant as per Ohm's Law.
Potentiostatic experiments such as cyclic voltammetry use a three electrode system consisting of a working electrode, a counter electrode, and a reference electrode. These are placed in an electrochemical cell containing the electrolyte solution and a reference solution. During a measurement, the potential of the reference electrode remains fixed while the potentiostat varies the potential of the working electrode. The counter electrode completes the circuit and allows current to flow, counteracting the redox events taking place at the working electrode due to electrochemical reactions in the cell, and ensuring that no current passes between the reference and working electrodes.
Potentiostat Specifications
Potential range | ±7.5 V |
Potential compliance | ±10 V |
Applied potential accuracy | ±10 mV offset |
Applied potential resolution | 333 μV |
Maximum current | ±200 mA |
Current ranges | ±20 μA to ±200 mA (5 ranges) |
Current measurement accuracy | ±20 nA offset (at 20 μA range) |
Current measurement resolution | 5 nA (at 20 μA range) |
Communication | USB-B |
Overall Dimensions | Width: 125 mm Height: 55 mm Depth: 175 mm |
Weight | 600 g |
Standard Electrochemical Cell Glassware (Optional)
Screw-fit PTFE lid with 3-electrode holes and 2-gas holes.

Platinum Disk Working Electrode (Optional)
Highly polished platinum embedded in polytetrafluoroethylene (PTFE) plastic bodies.
All dimensions are in millimetres.

Purity | 99.99% |
Diameter | 2 mm |
Platinum Wire Counter Electrode (Optional)
All dimensions are in millimetres.

Purity | 99.99% |
Diameter | 0.5 mm |
Non-aqueous Ag/Ag+ Reference Electrode (Optional)
All dimensions are in millimetres.