咨詢電話
0755-23003036
工作時間:(9:00-18:00 周一至周五)
- 澤任訂制
- FST動物實(shí)驗(yàn)器械
- 瑞士ideal-tek鑷子
- 瑞士Dumont鑷子
- Weller
- Techni-Tool
- 瑞士Rubis鑷子
- arosurgica
- Genesee Scientific
- Gilder Grids
-
Entegris
- WEICON
- ACCURIS
- AIMS
- RMC鉆石刀
- Sipel鑷子
- 德國WIHA
-
Si-Mat
- Jokari
- Circuitmedic
-
Glissando病理切片掃描儀
- KNIPEX(凱尼派克)
- Swann-morton
- Cellpoint Scientific
- Swanstrom
- All-spec
-
新華器械
- Excelta
- MENDA
- MEISEI
- Erem
- Regine
-
OPTRASCAN病理掃描儀
- Benchmark
-
IDEAL
- 大龍儀器
- 五洋醫(yī)療
- Hozan(寶山)
- 3M
- Stoelting
- Roboz
-
Diatome鉆石刀
- Fine Science Tools
- PLATO
- NanoSoft
-
Avantama
-
PSI打擊器及配件
- Aptum
- xuron
- SPI
- ASI Instruments
-
上海一恒
-
上海雷磁
- Quantifoil
- 上海方需
- 蘇州六六
-
Hamilton
- ISMART
-
顯微鏡
-
Bonllmann
- AVEN
- 塔望科技
-
瑞典Haglof激光測距儀
- STILLE
-
美國安維迪
- 德國貝朗蛇牌
- Medline
-
蛋白純化系統(tǒng)
-
OHAUS奧豪斯
- 康博特森
- Ossila
-
賽寧(蘇州)生物
- Bernstein
- 潔盟清洗機(jī)
-
Ted Pella
-
晶圓切割
-
Omniprobe FIB全鎢取樣針
-
新產(chǎn)品
-
矩陣
-
器械盒
-
切割套裝
-
手套
-
樣品盒
-
吸筆及吸盤
-
晶圓及晶圓盒
-
樹脂及耗材
-
金剛石懸浮液
-
實(shí)驗(yàn)室樣品瓶及杯子
-
實(shí)驗(yàn)室防護(hù)
-
石蠟
-
移液器及管
-
離心管及支架
-
計(jì)時器
-
玻片儲存盒
-
焊接棒
-
微型小鏟
-
夾持器及微針
-
耳標(biāo)及耗材
-
縫合夾及縫合針
-
放大鏡
-
止血鉗
-
氮化硅膜
-
耗材
-
導(dǎo)電膠及膠帶
-
骨剪及剪刀
-
膠帶及標(biāo)簽
-
顯微載玻片
-
碳粉及碳棒
-
切片機(jī)刀片
-
切片模具
-
電鏡載網(wǎng)
-
刀類
-
化學(xué)生物制樣
-
組織標(biāo)記染料
-
鉗子
-
樣品臺
-
拋光布
-
藍(lán)寶石基片
-
吸筆
-
打孔器
-
云母片
-
AFM用品
-
鉆石劃線筆
-
樣品臺盒
-
筆
-
儀器
-
晶圓鉗
-
晶圓切割
- DSI
- Keller
-
Smart Tweezers
- 瑞士PB
-
Microscopes Internat...
- Lattice Gear
-
凱氏定氮儀
- lindstrom
- 美國EMS
-
1-material
-
儀器
- realisticflies
- Boive
- Zivic
Scanning Thick Sections
Techniques for Scanning Impossibly Thick Specimens
In slide preparation, typical tissue sections are really thin—4 to 8 microns thin. This makes focusing fairly straightforward for computer software. But, what happens when the specimen or section is really thick (100-400 microns) or has wide variations in thickness across the region of interest? That's a lot more difficult.
Thick sections have important details that require focus changes of tens or even hundreds of microns. When some features are perfectly focused, other features (in the same field of view) can become completely invisible (due to the extreme difference in focus).
If the specimen was only a little thick (10-20 microns), we could use an objective that has a very high depth of field. A 10x 0.3NA objective might work well. But, the depth of field of that objective is nowhere near 400 microns. And, to get the extra depth of field you must give up magnification and resolution.
Fortunately, we have two suggestions for scanning those really thick sections: Image Stacking and EDF (Extended Depth of Field) Processing. These methods are complementary and are best when used together.
Image Stacking
A technique known as image stacking or multi-layer scanning is the first part of a solution to this problem. It involves scanning each field of a specimen at multiple focus layers. A whole slide image is created for each "layer" and an image viewer provides a way to navigate the image and the various layers. Image stacking comes with some requirements and caveats:
§ Each layer is located at a fixed distance from the prior layer. This distance must be less than the depth of field of the objective in order for everything to be in focus on one layer or another.
§ The time required to scan the specimen increases dramatically when there are a large number of scanned layers (which may be the case for very thick specimens).
§ Lower magnification (greater depth of field) is required to keep the scan time reasonable.
§ Image sizes increase as well. Rather than one image that is 500MB, you could end up with 20 images that are 500MB each for a total of more than 10GB.
The following images show different layers at various objective positions. Red arrows point to the different features that are in focus in each layer.
Scanning Thick Sections
Techniques for Scanning Impossibly Thick Specimens
In slide preparation, typical tissue sections are really thin—4 to 8 microns thin. This makes focusing fairly straightforward for computer software. But, what happens when the specimen or section is really thick (100-400 microns) or has wide variations in thickness across the region of interest? That's a lot more difficult.
Thick sections have important details that require focus changes of tens or even hundreds of microns. When some features are perfectly focused, other features (in the same field of view) can become completely invisible (due to the extreme difference in focus).
If the specimen was only a little thick (10-20 microns), we could use an objective that has a very high depth of field. A 10x 0.3NA objective might work well. But, the depth of field of that objective is nowhere near 400 microns. And, to get the extra depth of field you must give up magnification and resolution.
Fortunately, we have two suggestions for scanning those really thick sections: Image Stacking and EDF (Extended Depth of Field) Processing. These methods are complementary and are best when used together.
Image Stacking
A technique known as image stacking or multi-layer scanning is the first part of a solution to this problem. It involves scanning each field of a specimen at multiple provides a way to navigate the image and the various layers. Image stacking comes with some requirements and caveats:
§ Each layer is located at a fixed distance from the prior layer. This distance must be less than the depth of field of the objective in order for everything to be in focus on one layer or another.
§ The time required to scan the specimen increases dramatically when there are a large number of scanned layers (which may be the case for very thick specimens).
§ Lower magnification (greater depth of field) is required to keep the scan time reasonable.
§ Image sizes increase as well. Rather than one image that is 500MB, you could end up with 20 images that are 500MB each for a total of more than 10GB.
The following images show different layers at various objective positions. Red arrows point to the different features that are in focus in each layer.