產(chǎn)品中心
- 澤任訂制
- FST動(dòng)物實(shí)驗(yàn)器械
- 瑞士ideal-tek鑷子
- 瑞士Dumont鑷子
- Weller
- Techni-Tool
- 瑞士Rubis鑷子
- arosurgica
- Genesee Scientific
- Gilder Grids
-
Entegris
- WEICON
- ACCURIS
- AIMS
- RMC鉆石刀
- Sipel鑷子
- 德國(guó)WIHA
-
Si-Mat
- Jokari
- Circuitmedic
-
Glissando病理切片掃描儀
- KNIPEX(凱尼派克)
- Swann-morton
- Cellpoint Scientific
- Swanstrom
- All-spec
-
新華器械
- Excelta
- MENDA
- MEISEI
- Erem
- Regine
-
OPTRASCAN病理掃描儀
- Benchmark
-
IDEAL
- 大龍儀器
- 五洋醫(yī)療
- Hozan(寶山)
- 3M
- Stoelting
- Roboz
-
Diatome鉆石刀
- Fine Science Tools
- PLATO
- NanoSoft
-
Avantama
-
PSI打擊器及配件
- Aptum
- xuron
- SPI
- ASI Instruments
-
上海一恒
-
上海雷磁
- Quantifoil
- 上海方需
- 蘇州六六
-
Hamilton
- ISMART
-
顯微鏡
-
Bonllmann
- AVEN
- 塔望科技
-
瑞典Haglof激光測(cè)距儀
- STILLE
-
美國(guó)安維迪
- 德國(guó)貝朗蛇牌
- Medline
-
蛋白純化系統(tǒng)
-
OHAUS奧豪斯
- 康博特森
- Ossila
-
賽寧(蘇州)生物
- Bernstein
- 潔盟清洗機(jī)
-
Ted Pella
-
晶圓切割
-
Omniprobe FIB全鎢取樣針
-
新產(chǎn)品
-
矩陣
-
器械盒
-
切割套裝
-
手套
-
樣品盒
-
吸筆及吸盤(pán)
-
晶圓及晶圓盒
-
樹(shù)脂及耗材
-
金剛石懸浮液
-
實(shí)驗(yàn)室樣品瓶及杯子
-
實(shí)驗(yàn)室防護(hù)
-
石蠟
-
移液器及管
-
離心管及支架
-
計(jì)時(shí)器
-
玻片儲(chǔ)存盒
-
焊接棒
-
微型小鏟
-
夾持器及微針
-
耳標(biāo)及耗材
-
縫合夾及縫合針
-
放大鏡
-
止血鉗
-
氮化硅膜
-
耗材
-
導(dǎo)電膠及膠帶
-
骨剪及剪刀
-
膠帶及標(biāo)簽
-
顯微載玻片
-
碳粉及碳棒
-
切片機(jī)刀片
-
切片模具
-
電鏡載網(wǎng)
-
刀類(lèi)
-
化學(xué)生物制樣
-
組織標(biāo)記染料
-
鉗子
-
樣品臺(tái)
-
拋光布
-
藍(lán)寶石基片
-
吸筆
-
打孔器
-
云母片
-
AFM用品
-
鉆石劃線筆
-
樣品臺(tái)盒
-
筆
-
儀器
-
晶圓鉗
-
晶圓切割
- DSI
- Keller
-
Smart Tweezers
- 瑞士PB
-
Microscopes Internat...
- Lattice Gear
-
凱氏定氮儀
- lindstrom
- 美國(guó)EMS
-
1-material
-
儀器
- realisticflies
- Boive
- Zivic
產(chǎn)品詳情
簡(jiǎn)單介紹:
SPI經(jīng)銷(xiāo)商、原裝進(jìn)口、質(zhì)量保證、任何產(chǎn)品問(wèn)題請(qǐng)聯(lián)系我司銷(xiāo)售。
詳情介紹:
SPI Supplies Plasma Prep III Plasma Cleaner for TEM Holder, 110v:
The SPI Plasma Prep? III Plasma Cleaner is a compact "bench top" sized plasma cleaner, that uses the "dry plasma process" for the removal of contamination on the TEM specimen holder. The unit can also be used on the sample itself, whether in regards to the cleaning of the sample, or exposing it to a glow discharge process.
The unit is the same type of plasma cleaner instrument that was used by Dr. Nestor Zaluzec in the discovery that if this kind of contamination is removed, the contamination rates on samples are greatly reduced, and therefore, one sees a significant increase in the contrast and over all quality of the data in the final TEM image. Now this unit has been upgraded to the solid state technology for even better control over the power needed. SPI Supplies manufactures and offers for sale plasma cleaning equipment for this purpose according to the terms of a license agreement granted by Argonne National Laboratory
Special features:
Capable of 1 to 100 watt operation with most work done in the 1 to 10 watt range. This low wattage allows operation with argon without having deleterious impact on either the specimen holder, rod, or the specimen itself. This low power is enough to dislodge surface held contamination but not enough to actually "etch" the sample or rod or holder assembly.
Barrel type design for isotropic plasma cleaning which is the ideal geometry of the plasma to get into the various "nooks and crannies" of the specimen holder and contact areas between the specimen itself and the holder assembly.
Air vent bleed control valve: Allows operator to precisely control the rate of air flow when venting to the chamber. A sudden rush of air could disturb a fragile sample. The valve is easily accessible inside the cabinet of the plasma cleaner but discourages the changing of the bleed rate
Compact, Efficient Design: Small footprint, with room inside to process samples in batch quantities. Dimensions: 10- 1/2" (26.7cm)H x 14-3/4" (37.5cm)L x 12" (30.5cm)W; chamber is 4" (10.15) internal diameter, 6" (15.25cm) deep.
Highly portable: Weight is only 32 lbs (14.5kg), not including the weight of the separately installed rotary ("mechanical") pump. We suggest the Pfeiffer DUO pump
Make sure you appreciate the following:
Sometimes there is some confusion of the terminology, that is, what is a plasma etcher vs. what is a plasma cleaner. Generally speaking, a plasma etcher is a unit that operates at 100 watts or higher but a plasma cleaner operates at power levels perhaps as low as 1 watt and is designed to "tickle" the top surface of anything it sees. So for the purpose of removing thin adsorbed layers of contamination on a TEM foil sample for example, or on the sample holder itself, a low power plasma cleaner will do the job just fine. Indeed, using argon for example, at higher power could actually "etch" and cause damage to the metal parts of the microscope stage.
The Plasma Prep? III Plasma Cleaner is based on the same design as the Plamsa Prep? III solid state system. If your application is to remove photoresist, for example, from a silicon wafer, then what you really do need is a plasma etcher capable of running at 100 watts and so we would recommend our SPI Plasma Prep? III unit (this also has a larger chamber access).
Operation is simple...
Insert the rod and holder assembly into the glass reaction chamber, introduce your choice of gas, either oxygen or argon (depending on the specimen being examined), to the base pressure of approximately 250 mTorr and apply RF power (13.56 MHz) to the chamber. This excites the gas molecules present to a highly reactive plasma state. At the 10 watt operation level (or less), the plasma will easily be able to remove the slightly held contamination that is responsible for loss of contrast and image quality in most TEMs. For those looking to work with two gases or a mixture of the two, please see our Plasma Prep? III Process Controller for more information on this added module.
For those who have a Plasma Prep III or those considering the purchase of this system, one can consider obtaining the Plasma Prep III Plasma Cleaner Module. This kit would enable a user to change the front piece going from the standard Plasma Prep III to the Plasma Cleaner for TEM Specimen Holders.
Plasma Prep? III Plasma Cleaner - Operation
The SPI Plasma Prep? III Plasma Cleaner is a compact "bench top" sized plasma cleaner, that uses the "dry plasma process" for the removal of contamination on the TEM specimen holder. The unit can also be used on the sample itself, whether in regards to the cleaning of the sample, or exposing it to a glow discharge process.
The unit is the same type of plasma cleaner instrument that was used by Dr. Nestor Zaluzec in the discovery that if this kind of contamination is removed, the contamination rates on samples are greatly reduced, and therefore, one sees a significant increase in the contrast and over all quality of the data in the final TEM image. Now this unit has been upgraded to the solid state technology for even better control over the power needed. SPI Supplies manufactures and offers for sale plasma cleaning equipment for this purpose according to the terms of a license agreement granted by Argonne National Laboratory
Special features:
Capable of 1 to 100 watt operation with most work done in the 1 to 10 watt range. This low wattage allows operation with argon without having deleterious impact on either the specimen holder, rod, or the specimen itself. This low power is enough to dislodge surface held contamination but not enough to actually "etch" the sample or rod or holder assembly.
Barrel type design for isotropic plasma cleaning which is the ideal geometry of the plasma to get into the various "nooks and crannies" of the specimen holder and contact areas between the specimen itself and the holder assembly.
Air vent bleed control valve: Allows operator to precisely control the rate of air flow when venting to the chamber. A sudden rush of air could disturb a fragile sample. The valve is easily accessible inside the cabinet of the plasma cleaner but discourages the changing of the bleed rate
Compact, Efficient Design: Small footprint, with room inside to process samples in batch quantities. Dimensions: 10- 1/2" (26.7cm)H x 14-3/4" (37.5cm)L x 12" (30.5cm)W; chamber is 4" (10.15) internal diameter, 6" (15.25cm) deep.
Highly portable: Weight is only 32 lbs (14.5kg), not including the weight of the separately installed rotary ("mechanical") pump. We suggest the Pfeiffer DUO pump
Make sure you appreciate the following:
Sometimes there is some confusion of the terminology, that is, what is a plasma etcher vs. what is a plasma cleaner. Generally speaking, a plasma etcher is a unit that operates at 100 watts or higher but a plasma cleaner operates at power levels perhaps as low as 1 watt and is designed to "tickle" the top surface of anything it sees. So for the purpose of removing thin adsorbed layers of contamination on a TEM foil sample for example, or on the sample holder itself, a low power plasma cleaner will do the job just fine. Indeed, using argon for example, at higher power could actually "etch" and cause damage to the metal parts of the microscope stage.
The Plasma Prep? III Plasma Cleaner is based on the same design as the Plamsa Prep? III solid state system. If your application is to remove photoresist, for example, from a silicon wafer, then what you really do need is a plasma etcher capable of running at 100 watts and so we would recommend our SPI Plasma Prep? III unit (this also has a larger chamber access).
Operation is simple...
Insert the rod and holder assembly into the glass reaction chamber, introduce your choice of gas, either oxygen or argon (depending on the specimen being examined), to the base pressure of approximately 250 mTorr and apply RF power (13.56 MHz) to the chamber. This excites the gas molecules present to a highly reactive plasma state. At the 10 watt operation level (or less), the plasma will easily be able to remove the slightly held contamination that is responsible for loss of contrast and image quality in most TEMs. For those looking to work with two gases or a mixture of the two, please see our Plasma Prep? III Process Controller for more information on this added module.
For those who have a Plasma Prep III or those considering the purchase of this system, one can consider obtaining the Plasma Prep III Plasma Cleaner Module. This kit would enable a user to change the front piece going from the standard Plasma Prep III to the Plasma Cleaner for TEM Specimen Holders.
Plasma Prep? III Plasma Cleaner - Operation