產品中心
- 澤任訂制
- FST動物實驗器械
- 瑞士ideal-tek鑷子
- 瑞士Dumont鑷子
- Weller
- Techni-Tool
- 瑞士Rubis鑷子
- arosurgica
- Genesee Scientific
- Gilder Grids
-
Entegris
- WEICON
- ACCURIS
- AIMS
- RMC鉆石刀
- Sipel鑷子
- 德國WIHA
-
Si-Mat
- Jokari
- Circuitmedic
-
Glissando病理切片掃描儀
- KNIPEX(凱尼派克)
- Swann-morton
- Cellpoint Scientific
- Swanstrom
- All-spec
-
新華器械
- Excelta
- MENDA
- MEISEI
- Erem
- Regine
-
OPTRASCAN病理掃描儀
- Benchmark
-
IDEAL
- 大龍儀器
- 五洋醫(yī)療
- Hozan(寶山)
- 3M
- Stoelting
- Roboz
-
Diatome鉆石刀
- Fine Science Tools
- PLATO
- NanoSoft
-
Avantama
-
PSI打擊器及配件
- Aptum
- xuron
- SPI
- ASI Instruments
-
上海一恒
-
上海雷磁
- Quantifoil
- 上海方需
- 蘇州六六
-
Hamilton
- ISMART
-
顯微鏡
-
Bonllmann
- AVEN
- 塔望科技
-
瑞典Haglof激光測距儀
- STILLE
-
美國安維迪
- 德國貝朗蛇牌
- Medline
-
蛋白純化系統(tǒng)
-
OHAUS奧豪斯
- 康博特森
- Ossila
-
賽寧(蘇州)生物
- Bernstein
- 潔盟清洗機
- Ted Pella
- DSI
- Keller
-
Smart Tweezers
- 瑞士PB
-
Microscopes Internat...
- Lattice Gear
-
凱氏定氮儀
- lindstrom
- 美國EMS
-
1-material
-
儀器
- realisticflies
- Boive
- Zivic
產品詳情
簡單介紹:
SPI經(jīng)銷商、原裝進口、質量保證、任何產品問題請聯(lián)系我司銷售。
詳情介紹:
Leit-C? CCC Conductive Carbon Cement is electrically conductive, and was formulated specifically for the mounting of samples for examination by SEM.
Because of its electrical conductivity, all samples are ready for insertion into the SEM immediately after drying of the product. If it is a non-conductive specimen, then there is the strong likelihood that some kind of metallization would be preformed on the sample, such as by sputter coating or if a FESEM is being used, possibly even by osmium coating.
The Leit-C CCC conductive adhesive contains only carbon, hydrogen, and oxygen, therefore after drying, there would be no peaks detected by EDS other than the three elements, even with windowless detectors. If the entire specimen holder is "painted" with CCC, the cement will mask the holder and in general, one does not detect x-rays from the holder itself and would could interfere with x-rays from the specimen itself.
Some Additional Information:
The product is considered air drying and the application of heat is not necessary. For use in a UHV system, so long as it will not change the sample itself, a bake-out can be done up to 100°C. Going to higher temperatures should cause degradation of the small amount of acrylic polymer binder present. Also, as one uses the product, and there is evaporation of the carrier, addition of the special thinner will enable the user to maintain constant viscosity and carbon solids.
Choice of Thinners:
Because of its electrical conductivity, all samples are ready for insertion into the SEM immediately after drying of the product. If it is a non-conductive specimen, then there is the strong likelihood that some kind of metallization would be preformed on the sample, such as by sputter coating or if a FESEM is being used, possibly even by osmium coating.
The Leit-C CCC conductive adhesive contains only carbon, hydrogen, and oxygen, therefore after drying, there would be no peaks detected by EDS other than the three elements, even with windowless detectors. If the entire specimen holder is "painted" with CCC, the cement will mask the holder and in general, one does not detect x-rays from the holder itself and would could interfere with x-rays from the specimen itself.
Some Additional Information:
The product is considered air drying and the application of heat is not necessary. For use in a UHV system, so long as it will not change the sample itself, a bake-out can be done up to 100°C. Going to higher temperatures should cause degradation of the small amount of acrylic polymer binder present. Also, as one uses the product, and there is evaporation of the carrier, addition of the special thinner will enable the user to maintain constant viscosity and carbon solids.
Choice of Thinners:
We offer a choice of thinners, one being the "official" thinner formulated by the manufacturer of the Leit-C CCC adhesive product, and a second (and less expensive) one formulated by SPI Supplies.